Subject:      FTMH: SAS Notes for 04Dec2001: Similar equations yield different
              results on IEEE machines
Content-Type: multipart/alternative;

For the Mantissa-Heads:

> 006214 Similar equations yield different results on IEEE machines > SN http://www.sas.com/service/techsup/unotes/SN/006/006214.html

SN-006214 Similar equations yield different results on IEEE machines

On IEEE platforms (including Windows), floating point unit (FPU) registers offer greater precision than floating point memory locations. It is not uncommon in C code for the same expression appearing in different parts of a program to produce slightly different results, because the compiler keeps intermediate results for a computation in the FPU registers. This permits a higher degree of precision, since the floating point register has 12 extra bits for the mantissa and 4 extra bits for the exponent.

For example:

data _null_; p=1; p=p/100; q=1; q=q/100; r=p-q; put p= q= r=; run;

produces:

p=0.01 q=0.01 r=2.083701E-19

The value of R is not exactly 0. Internally, P is loaded in an FPU and divided by 100. The result is written to memory, which causes the processor to convert the value from an 80-bit to a 64-bit floating point number. Q is then loaded and divided by 100. The result is again written to memory but an additional floating point store instruction is executed, causing the result in the FPU to not be discarded. The subtraction is performed, which results in the slight difference in the generated result . The difference would be zero if P was reloaded to an FPU prior to the subtraction.

The workaround is to specify the undocumented option NOCODEGEN.

Product:Base SAS Component:SAS data sets (OS) Priority:N/A Status:Usage Issue Date:Mon, 5 Nov 2001

SystemVersion ReportedVersion Fixed AIX/6000 7 TSP1 Compaq Tru64 UNIX 7 TSP1 HP-UX Operating Systems 7 TSP1 IBM OS/2 7 TSP1 Solaris 7 TSP1 Windows NT 7 TSP1 Windows 95 7 TSP1 Windows 98 7 TSP1 Unless otherwise stated above, no fixes are available for this issue.