Date:         Wed, 17 Nov 2004 11:59:17 -0500
Reply-To:     CICS List <CICS-L@LISTSERV.UGA.EDU>
Sender:       CICS List <CICS-L@LISTSERV.UGA.EDU>
From:         "Weiss, Mark" <Mark.Weiss@COMPUWARE.COM>
Subject:      Re: STGPROT=YES
Content-Type: text/plain; charset="iso-8859-1"

Herbie,

With STGPROT=YES and TRANISO=YES, it is likely - although not a guarantee - that the perp is somewhere within the task that owned the storage CICS detected the violation in. I said "not a guarantee" because you should also consider any TRUEs and/or GLUEs active in the environment.

Good luck, Mark Weiss

-----Original Message----- From: CICS List [mailto:CICS-L@LISTSERV.UGA.EDU]On Behalf Of Van Dalsen, Herbie Sent: Wednesday, November 17, 2004 11:49 AM To: CICS-L@LISTSERV.UGA.EDU Subject: STGPROT=YES

Hi all,

I haven't been paying close attention to changes in CICS the last few years, We have STGRCVY=NO STNTR=OFF SYSIDNT=CICP SYSTR=OFF TCT=NO TRANISO=YES

in the sysin,

Yet... This happened today,

+DFHSM0102 CICSPROD A storage violation (code X'0F0C') has been detected

I was hoping that the perpotraitor would go down S0C1 ?

Regards

Herbie

-----Original Message----- From: CICS List [mailto:CICS-L@LISTSERV.UGA.EDU] On Behalf Of D'Antonio Carl J. (SYS1CJD) Sent: Wednesday, November 17, 2004 4:08 PM To: CICS-L@LISTSERV.UGA.EDU Subject: Recall: RKANPAR.GLOBALS

The sender would like to recall the message, "RKANPAR.GLOBALS". **************************************************************************** ***************** This email and any attachments are confidential and intended for the sole use of the intended recipient(s).If you receive this email in error please notify emailadmin@euroconex.com and delete it from your system. Any unauthorized dissemination, retransmission, or copying of this email and any attachments is prohibited. Euroconex does not accept any responsibility for any breach of confidence, which may arise from the use of email. Please note that any views or opinions presented in this email are solely those of the author and do not necessarily represent those of the Company. This message has been scanned for known computer viruses. **************************************************************************** *****************

The contents of this e-mail are intended for the named addressee only. It contains information that may be confidential. Unless you are the named addressee or an authorized designee, you may not copy or use it, or disclose it to anyone else. If you received it in error please notify us immediately and then destroy it.


Back to: Top of message | Previous page | Main CICS-L page